Technical Parameters
Configuration list
It is used for testing the electromagnetic shielding effectiveness of electromagnetic shielding materials, such as textiles, plastic cloth, metal sheet, non-conductive material surface coating or coating, metal mesh, conductive film, conductive glass and conductive dielectric plate.
GB/T 23326 Electromagnetic shielding of stainless steel fiber and cotton polyester blended fabric
GB/T 25471 Measurement method of shielding effectiveness of electromagnetic shielding coatings 
SJ 20524 Measurement method of shielding effectiveness of materials ASTM 4935
Principle of instrument:
乐博体育·(中国集团)有限公司官方网站
Structure diagram
1. Shielding effectiveness(SE)
The logarithm of the ratio of the power or voltage received by the shielding material to the unshielded material at the same excitation level. The formula is as follows:
乐博体育·(中国集团)有限公司官方网站
乐博体育·(中国集团)有限公司官方网站  乐博体育·(中国集团)有限公司官方网站
VO—Receiving voltage of unshielded material
VI—Receiving voltage with shielded material
PO—Receiving power of unshielded material
PI—Receiving power with shielded material
2. Test process
According to the standard GBT25471-2010, the test and the dampness are taken. First, the reference sample is used to measure at multiple frequency points, and the recorded value is PO (or VO) at each frequency. Then the measurement sample is measured at multiple frequency points, and the recorded value is PI (or VI) at each frequency. The shielding effectiveness is calculated with the above formula.
Signal source
Test frequency range
300KHz~3000MHz
Frequency stability
≤±5×10-6
Frequency resolution
1Hz
Signal purity
≤-65dBc/Hz(Partial 10KHz)
Output level
-45dBm~+10dBm
Level accuracy
≤±1.5dB(25℃±5℃ ,-45dBm~+5 dBm)
Harmonic suppression ratio
≥30dB(1MHz~3000MHz) ,≥25dB(300KHz~1MHz)
Directional
≥50dB(After vector calibration)
Power scanning
-8dBm~+5dBm
System impedance
50 Ohm(Type A)、75 Ohm(Type B)
Receiver
Frequency range
300KHz~3000MHz
Resolution bandwidth
100Hz~20KHz
Dynamic range
≥95dB ( RBW=1KHz )
Maximum input level
+10dBm
Input damage level
+20dBm(Direct +25V )
Port
Bobbi ≤1.2